Door intercom systems Intercom systems Accessories for BUS door intercom systems

Kleines 1×1 zum Aufbau einer Videosprechanlage

Intercom with video 2 wire
In principle, one can say they need for each intercom einen BUS-Trafo und eine DPS (BUS Signalgeber) oder eine PC6 welche den PS5 oder PS4 und die DPS ersetzt .
For the capacitive door intercom systems Monitors of the T series (T37, 47 ....) they should use the PC6 because this in combination with the SC6 the Haussprechanlage to the image memory counter-intercom.


Modelle, Bezeichnung und Funktion

DB1 Table mount for all intercom monitors

black o white

  • Table holders for all monitors
  • also suitable for SH-G70 Alam system

PC6A Power Comb BUS Supply & Data Combination unit for video door intercom

Video door intercoms Combination unit from power supply and DPS an additional DPS is not necessary.
Eine PC6 ist ausreichend für die Versorgung von 4-6 Monitoren im zeitgleichen Betrieb (Einfamilienhaus) .
For larger video door intercom systems, we recommend BDU amplifiers / PC6A combinations. Ask for our TEC support

Input Voltage: 100 ~ 240 VacInput
Frequency: 50 ~ 60Hz Rated
Output Voltage: DC 28V + 2V
Rated Output Current: 1.5A
Working Temperature: -10 ° C ~ 55 ° C
Dimension: 140 * 90 * 60mm

Port Description:
PG. Power Ground / Erdung (grün/gelb)
N: AC input N
L: AC input L
CN2 : Sprechanlagen BUS Brück bleibt immer gesetzt
BUS IM: line to video door bell monitor
BUS DS line to the video door intercom station


SC6M /SC6V Modul

f. external image memory /

DVR Anschluss /2x DT Cam

only in conjunction with PC6

Hutschienen Sprechanlagen Modul SC6M für Monitore ab T Serie in kombination mit PC6 Licht /Schloss Steuerung über den Monitor (nur in Verbindung mit PC6+SC6M)
Bildspeicher (nur in Verbindung mit PC6+SC6M) 2x BUS 2 Draht Kameras anschließbar (DT-CAM) Codierung über DIP Codes entfällt
Basically, SC6M is not compatible with other DT BUS
Intercom units and DT bus intercom systems Components of the company Schick intercoms are backwards compatible but can optionally be operated with a new Txx monitor.

The image memory function, previously referred to as SD function
but the picture of the visitor is not over the
Door intercom monitors are saved
optional SC6M module which can only be operated in conjunction with the PowerComb PC6 intercom systems.

SD function and also model DtxxSD TD XX is omitted.
The SC6M module can also be equipped with additional bus cameras
(only) in conjunction with the T47 monitor.
The special feature of the SC6M module:
Even with larger systems -32 WE only 1 central SC6M module is needed for the image memory, which saves considerable costs against the monitors with SD function



PS4 12V

Hutschienen Adapter für Türöffner 12V

for BUS intercom systems

70 x 89 x 45 mm / 0,37 Kg

Eingang 85~ 260 Vac

24 V DC / 1 A Ausgang

  • DIN Hutschienen Adapter für DT System für die Montage in den bauseitigen Verteilerschrank

  • suffice for 2 video calls

  • für Türöffner 12 V > 300 mA an Sprechanlage


DPS

Stromversorgungs Controller

for BUS intercom systems

70 x 89 x 45 mm / 0,37 Kg

Stromseperator für die Verbindung

Türklingel /Monitor/e in Verbindung nur mit PS4 oder PS5


DT-SCU camera interface for intercom system

Intercom camera interface for BUS intercom systems
DT-SCU
The DT-SCU model was developed to feed external cameras into the BUS of the intercom system.
Die SCU ist kompatibel mit allen Modellen auch früherer Baureihen (dort aber auf DCU Modus umstellen )
Es können 2 x analoge Kameras CCD eingespeist und 2 BUS (2 Draht Kameras /Modell DT-Cam) an einen SCU Sprechanlagen Interface eingebunden werden .
Jede im System verbaute SCU benötigt eine Türstation gleicher ID im SCU Modus im DCU Modus bekommt jede SCU die ID einer Türstation ID 00 01 10 11 max 4 RS-485 : reserviert CAM 1~2 : Anschluss für 2 analog (Kamera Typ A) CAM 3~4 : Anschluss für 2 Draht BUS Kamera (Kamera Typ B) BUS (IN) : Eingang BUS Line BUS (OUT) Ausgang BUS Line Tasten : betätigen CAM1 ~4 Tasten /Einstellung und Kontrolle der entsprechenden Kameras

PS5

PS5

0,64 Kg

DIN rail adapter

for BUS intercom systems

150 x 97 x 38 mm

  • Overvoltage, overheating, short circuit protected
  • DIN rail mounting (control cabinet)
  • ausreichend für – 32 Monitore normal und 16 SD Monitore
  • ausreichend für – 4 DMR11
  • 230V 47-63Hz /Ausgang 24Vdc + 26,5 Vdc (einstellbar) 4,5 A
  • Eingang 100~120VAC(2.5A), 200~240VAC(1.5A)
  • Working temperature -20 ° C ~ + 60 ° C
  • To be used for systems> 2 indoor units

  • L(AC): AC input. / Wechselstromanschluss 230V
  • N (AC): AC input. / AC connection 230 V
  • Earth Ground. /Schutzleiter (grün/gelb
  • V-: DC power Output.(21.5~26.5 einstellbar) zum DPS verbinden
  • V +: DC Power output (21.5 ~ 26.5 settable)) to DPS connection
  • VADJ: Einstellen Ausgangsstromstärke (Potentiometer).
  • LED: Working state indicatior.

Signal distributor DBC4A1 for intercom system 4 outputs

DBC-4A Signal distributor for video door intercom system
Monitors and door bells

We recommend using the DBC4A for star distribution of the intercom units.
Per BUS harness a video door phone cockpit monitor or a door station.
Die Sternverteilung ist bei einer Sprechanlage von mehr als 4 Video Türsprechanlagen Monitoren die empfohlene Installationsform.
Bei Fragen hierzu kontaktieren sie unseren TEc Support

Distributor DBC4A:
Abmessung: 89*70*45mm
Supply via BUS: 20- 30V Do not observe polarity
Connection ports for monitors or door intercom ABCD
Impendance Switch to ON on the last DBC4A1 of the BUS

4 Outputs Splitter:
? Für Mehrtorstationen und Monitor in Sternverteilung (max.4);
? Separate insulation protection;
? Short-circuit indicator;
? Periodic self-recognition.

(Star-shaped) of the signal on 4 individual loudspeaker monitors or door handles (required depending on construction) DIN rail mounting

Audiostation for intercom

DJ4A Intercom doorphone auditorium

187x97x33mm

  • Audiostation für DT Videosprechanlagen
  • Tiled floor connection
  • DIP Address Settings
  • max 128 addresses without BDU
  • Internal call available / no intercom
  • 2 door opener controllable
  • compatible with all intercom systems

This intercom station is very well suited for installation as a Slaverstation in a family or multi-family house. Especially for houses with very large apartments it is sometimes necessary to install several devices or additional bells in order to ensure a sufficient volume of the door bell.
With these loudspeaker audio indoor stations, they have the advantage of an extra gong that no additional supplies etc. are necessary and no complicated connections to the monitor have to be made via decoupling relays etc.
The audio speech station station is simply clamped at any point on the BUS gets a Slaver programming and already ringing with the desired monitor parallel with.
You can also talk and open ...

DJ5A Audiostation for intercom system

DJ5 SpeakerphoneAudiostation for single-family house and multi-family house intercom

88 (H) x110 (W) x20 (D) mm

This intercom station is very well suited for installation as a Slaverstation in a family or multi-family house. Especially for houses with very large apartments it is sometimes necessary to install several devices or additional bells in order to ensure a sufficient volume of the door bell.
With these loudspeaker audio indoor stations, they have the advantage of an extra gong that no additional supplies etc. are necessary and no complicated connections to the monitor have to be made via decoupling relays etc.
The audio speech station station is simply clamped at any point on the BUS gets a Slaver programming and already ringing with the desired monitor parallel with.
You can also talk and open ...

Power Supply: DC 24V
Power Consumption: Standby 16mA Working status 56mA
Working Temperature: -15 ° C ~ + 55 ° C
Wiring: 2 wires, non-polarity
Dimension: 88 (H) × 110 (W) × 20 (D) mm
Id Address can be set via DIP CodesMax 128 DIP addresses
Inner call function for MFH if several call stations in a WE
Door opener control 2x
4 Ringtones adjustable
compatible with multi-family house and family house intercom DT system

Achtung im MFH nur als Slaver Station einsetzbar und nicht als Hauptstation da keine Etagenruf Taster angeschlossen werden kann

DT-BDU router / amplifier / gateway mode

2 wire BUS intercom amplifier and router

Endlich ist es soweit und wir können nun Türsprechanlagen Systeme bis zu 128 Wohnungen in einen Sprechanlagen System abbilden.

Also difficult routing routes in existing mixing cabling or with too thin cross-sections are no longer a problem with the DT-BDU / SH.

  • For long distances up to 480 m
  • größer Sprechanlagenkapazität bis zu 128 Sprechanlagen Einheiten
  • Repeater mode
  • Router mode for 4 Area

Application:

  1. Too small cross sections <0,6 and too long distances as repeaters

, System repeater for cables that are too long and too thin with multiple monitors

For apartment intercom systems up to 128 intercom monitors


DT-QSW Camera Interface 4 Cameras in Quad View

Intercom camera interface for BUS intercom systems

DT-QSW Modell wurde entwickelt um 4 externe Kameras analoge in den BUS der Sprechanlage einzuspeisen .
A separate supply of the cameras is needed, for example via PS4 12 V

Die QSW ist kompatibel mit allen Modellen ab T37 Es können pro SCU 4 x analoge Kameras CCD eingespeist
to an SCU Interpreter Interface.
From the monitors T37MG-V2 and DT31M, it is possible to display all cameras on a QSW simultaneously in quad view. 4 QSW with 4 cameras is possible

Image of a quad-view
Video

Power Supply: DC24V;

Working Temperature: -150C ~ + 550C;

Wiring: 2 wire, non-polarity;?Dimension: 90 (H) × 72 (W) × 60 (D) mm.

DT-RLC tamper-resistant relay contact or light module

Das DT-RLC BUS Relaismodul

Das RLC Modul ist ein Schlossmanagement Modul im Sicherheitsrelevanten Bereich für dem direkten Anschluss im Hausverteiler auf DIN Hutschiene (manipulationssicher ) Anschluss 1 x Türöffner, Motorschloss o.ä.
For high power consumption of the door opener
tamper-proof connection in the house distributor
Lcontrol mode for light control einstellbar
adjustable opening time
Taster anschließbar (getaktet )

Für sichere Schlosskontrolle von TÖ 1 oder 2 bis zu 4 Türklingel -IDs für Motorschloss oder andere Sicherheitsrelevanten Schlösser ( manipulationssichere Steuerung)
The connection is made in the house distributor and is controlled via the BUS.
Since no access from the outside is possible, we have the possibility to connect safety-relevant components here.
Da der DT-RLC unabhängig vom verbauten Türöffner der Türklingel arbeitet können beide Kontakte ( an der Türklingel und am RLC ) gleichzeitig genutzt werden .
Connection 1 x Door opener per RLC possible, motor lock or similar.
Für hohe Leistungsaufnahme des Türöffners mit einstellbarer Öffnungsdauer
Button can be connected

Achtung Sprechanlagen Türschloss Hinweis :
Die Türklingeln DT601 S/KP, DT601F/KPbieten die Möglichkeit der Steuerung von 2 RLC Modulen mit dem Codebereich 1 und 2 ( Code Range ).
Die Türklingeln DT601S/ID, 601FP, DT601ID, DMR21 und DMR11SS Türöffner 1 (Codebereich 20-49 ) ein zweiter wird von außen nicht angesteuert.

Dieser Codebereich war bei dem Vorgängermodell Türklingel DT596 vorgesehen für den 2 . Öffneranschluss S2+ .
Dieser ist bei den Geräten der 601KP Serie entfallen . Dafür wird das Türöffner Signal als BUS Kommando, für S2 über den BUS übertragen und an das RLC gesendet .
So we have here a tamper-proof contact.
A control of the door opener via the RLC module by means of RFID in the door stations DMR11 and DMR18 is not possible until MJ2015 version S DMR118SCIDX S.

Das RLC Modul ist mit allen Monitoren bedingt abwärts kompatibel Der Türöffnerkontakt 2 am Monitor ist erst ab MJ 2014 (Modelle T39 T47 DT16CS ) verfügbar es wird sonst immer nur der 1. Türkontakt parallel zur angeschlossenen Türklingel angesprochen .

Anleitungen in deutsch und in Englisch finden sie im Downloadbereich Tech Support .

? Power Supply: DC24V;
? Unlocking Time: 1 ~ 30s (Default 1s);
? Lock Power supply: 12Vdc, 450mA (Internal Power);
? Working Temperature: -100 C ~ + 400 C;
? Dimension: 89 (H) × 71 (W) × 45 (D) mm.
Relais Kontakt max 10 A 277 VAC

Data sheet relay